DISASSEMBLY and REPLACEMENT
4 - 188
4.9.10 Fuser belt rotation detection sensor (S49)
(1) Take off the pressure roller cover.
P. 4-173"4.9.2 Pressure roller cover"
(2) Take off the transport guide-1.
P. 4-174"4.9.3 Transport guide-1"
(3) Take off the transport guide-2.
P. 4-174"4.9.4 Transport guide-2"
(4) Remove 1 screw and the bracket [1] of the
fuser belt edge thermistor.
(5) Remove 3 screws and take off the front
upper frame [2].
(6) Remove 1 screw and the bracket [3] of the
fuser belt rotation detection sensor.
(7) Release a harness from 1 clamp [4] and then
disconnect a connector [5].
Fig. 4-545
(8) Remove the fuser belt rotation detection
sensor from the bracket.
Fig. 4-546
[
1
]
[
2
]
[
3
]
[
4
]
[
5
]
Fuser belt rotation detection sensor