DISASSEMBLY and REPLACEMENT
4 - 200
4.9.19 Pressure roller contact/release clutch (CLT1)
(1) Take off the fuser unit.
P. 4-172"4.9.1 Fuser unit"
(2) Open the SYS board case.
P. 9-2"9.1.3 SYS board case"
(3) Release the harness from 2 clamps.
(4) Disconnect 2 connectors from the fuser
motor and pressure roller contact/release
clutch.
Fig. 4-579
(5) Disconnect the connector of the exit paper
cooling fan (rear). Then remove 2 screws
and take off the a duct.
(6) Remove 2 screws and take off the duct [1].
(7) Remove 1 screw and take off the bracket [2]
of the handle.
Fig. 4-580
(8) Remove 4 screws and take off the fuser drive
unit [1].
Notes:
When installing, do not let the harness be
caught. Be sure that 2 dowels [2] are
securely fitted into the holes of the fuser
drive unit.
Fig. 4-581
[
1
]
[
2
]
[
1
]
[
2
]
[
2
]

Table of Contents