SETTING ADJUSTMENT
6 - 7
6.1.4 Adjustment of Color Registration Control
After having finished the “Automatic initialization of image quality control (05-2742)” procedure, perform
the “Forced performing of color registration control adjustment (05-4719)” procedure.
Code Item to be adjusted Contents
4719 Forced performing of
color registration
control
<Procedure>
(A) While pressing [0] and [5] simultaneously, turn the power ON.
Adjustment Mode
(B) Key in [4719] and press the [START] button.
(C) “WAIT” is displayed.
(D) When the adjustment finishes normally, the equipment will return to initial
state of the Adjustment Mode.
When an error occurs
<When “Waste toner box replacement” is displayed>
P. 3-56"[E] Waste toner box replacement"
1. Replace the waste toner box with a new one and close the waste toner
box cover.
2. Press and hold the [ON/OFF] button for a few seconds to shut down the
equipment.
3. Turn the power ON.
4. Release the waste toner box full status by the warming-up operation.
5. Check that “Ready” is displayed.
6. Press and hold the [ON/OFF] button for a few seconds to shut down the
equipment.
7. Perform steps (A) to (D) in <Procedure>.
<When “ERROR” is displayed>>
(1)“ERROR” which occurs when toner is supplied
P. 3-54"[C] No toner in the cartridge"
1. Press the [CANCEL] button to return to the original state in the
adjustment mode in order to check the toner low status.
2. Press and hold the [ON/OFF] button for a few seconds to shut down the
equipment.
3. Turn the power ON.
4. Check the toner adding status in the warming-up operation.
When a message prompts you to replace the toner cartridge, open the
front cover and replace the cartridge with a new one.
(“Adding Toner” is displayed.)
5. Check that “Ready” is displayed.
6. Press and hold the [ON/OFF] button for a few seconds to shut down the
equipment.
7. Perform steps (A) to (D) in <Procedure>.
<Other abnormalities>
Take the appropriate action described in Troubleshooting.
P. 8-1"8. ERROR CODE and TROUBLESHOOTING"