DISASSEMBLY and REPLACEMENT
4 - 142
Notes:
Follow the procedure below for the
installation.
1. Place the dent of the cleaner on the stud
A, and hook the shaft on the portion B as
shown in the figure.
2. Place the front side of the unit on the
waste toner duct.
3. Press a label on the shutter with your
finger.
If shutter movement is bad, clean the
nozzle surface and shutter's inner
diameter area.
4. Fix the cleaner by pushing its upper side.
Fig. 4-414
Fig. 4-415
Notes:
When taking off the TBU cleaner, clean it if it
is dusty or stained [1].
When the film sheet indicated by the figure
gets dusty or stained
Fig. 4-416
A
B
Rear side Front side
Transfer belt cleaning unit
[
1
]
[
2
]