DISASSEMBLY and REPLACEMENT
4 - 145
(3) Take off the transfer belt unit [1] with its front
side up slantwise not to hit the motor on its
rear side to the equipment.
Notes:
When the transfer belt unit [1] or the lever
assembly is replaced, be sure to perform the
adjustment of the degree of parallelization for
the transfer belt unit [1].
Adjustment is not necessary when a part
other than those described above (such as a
roller) is replaced.
Fig. 4-423
Notes:
1. When installing, place the unit with its
rear side down slantwise. Make sure that
2 sections shown in the figure are
properly set.
2.
The power supply spring shown in the
figure supplies high-voltage bias from the
equipment to each roller. If any of these
springs is dirty, clean it. If it is deformed,
replace it with a new one.
3.
After the transfer belt unit is taken out,
install it securely in the equipment, and
then close the duplexing unit. If you close
the duplexing unit without having securely
installed the transfer belt unit, this may
damage the transfer belt or the 2nd
transfer roller, deform the 2nd transfer
front guide or cause the bearing on both
ends of the 2nd transfer roller to fall off.
Check points
Make sure that the process unit is
installed securely.
Check that the TBU locking lever is
locked.
Fig. 4-424
Fig. 4-425
[
1
]
YMCK
YMCK
2nd transfer facing
roller
1st transfer roller
1st transfer roller
2nd transfer facing roller