ERROR CODE and TROUBLESHOOTING
8 - 148
[CB92] Saddle Stitch Finisher RAM abnormality
[CB93] Saddle Stitch Finisher additional folding motor abnormality
[CB94] Saddle transport motor abnormality
Classification Error item
Finisher related service call
Check item Measures
Saddle controller PC board (SDL) Check if the conductor pattern on the saddle controller PC
board (SDL) is open circuited or short circuited.
Connector check
Board check
Replace parts Remarks
Saddle controller PC board
Classification Error item
Finisher related service call The [CB93] error also occurs when the error [EF18] has
occurred consecutively for 3 times.
Check item Measures
Additional folding carrierr Is there any mechanical problem when the additional
folding carrier is moved?
Connector check
Harness check
Additional folding motor (M20) Motor check
Connector check
Harness check
Saddle control PC board (SDL) Connector check (CN18)
Board check
Replace parts Remarks
Additional folding motor
Saddle control PC board
Classification Error item
Finisher related service call The [CB94] error also occurs when the error [EAB0] or [EF13]
has occurred consecutively for 3 times.
Check item Measures
Transport roller Is there any mechanical problem when the transport
rollers are rotated?
Saddle transport motor (M16) Motor check
Connector check
Harness check
Saddle control PC board (SDL) Connector check (CN18)
Board check