ERROR CODE and TROUBLESHOOTING
8 - 160
21 Compare them with the
statues of [G] and [H]
displayed in step 14.
Both [G] and [H] are changed - The image
position aligning sensors on both sides are
operating normally.
[G] remains same - The image position
aligning sensor on the rear side is not
operating normally.
[H] remains same - The image position
aligning sensors on the front side is not
operating normally.
Both [G] and [H] remains same - The image
position aligning sensors on both sides are
not operating normally.
22 Check how item [G] is displayed while [9] is
pressed.
23 Compare it with the statue of
[G] displayed in step 15.
[G] is changed - The image position aligning
sensor on the center side is operating
normally.
[G] remains same - The image position
aligning sensor on the center side is not
operating normally.
24 Press the [CLEAR] button.
25 Key in “167”, then press the [START] button.
(03-167: Image position aligning sensor / LED
OFF)
26 Key in “168”, then press the [START] button.
(03-168: Sensor shutter closed)
27 Turn the power OFF.
28 If the image position aligning sensors on all
sides are operating normally, proceed to step
(30). In other cases, proceed to step (29).
Step Check item Result Measures