ERROR CODE and TROUBLESHOOTING
8 - 168
[CE41] Image quality TRC control test pattern abnormality
7 Perform “Image quality
closed-loop control (05-
2742)” and make sure it is
completed normally. (Error
[CE40] does not appear.)
Then perform “Automatic
gamma adjustment”.
Normal 9
When
an error
occurs
Check and correct it accordingly.
8 Clear all “Image quality
control abnormal detection
counter Y to K display/0
clearing (08-2528 to 2531)”.
9 Check if any of the springs
for supplying power to the
transfer belt unit is
deformed. Replace the
spring if it is deformed.
Classification Error item
Image control related service call The image quality TRC control test pattern is not printed
normally.
Step Check item Result Measures
Next
step