UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 9
For BRIA PKG Setup
ISDN Line Number 01~04
Item
No
Item Input Data Default
01
ISDN Line Mode
0 = No setting
1=T-Point
2 = S-Point (OT)
3 = NW Mode (Leased Line) (OT)
4 = NW Mode (Interconnected
Line) (OT)
5 = NW Mode (Interconnected
Line, Fixed Layer1=NT) (OT)
6 = S-Point (Leased Line) (OT)
1
02
Logical Port Number
The starting port number of a BRI
line is displayed. Two logic ports are
automatically assigned to a BRI line.
[0:No setting] = 0
[1:T-Point] = 1-200
[2:S-Point] = 1-512 (OT)
[3:NW Mode (Leased Line)] = 0 (OT)
[4:NW Mode (Interconnected Line)]
= 0 (OT)
[5:NW Mode (Interconnected Line,
Fixed Layer1=NT)] = 0 (OT)
[6:S-Point (Leased Line)] = 1-512
(OT)
0
03
Connection Type
0 = Point-to-Multipoint
1 = Point-to-Point
0
04
Layer 3 Timer Type
Each timer value of Layer 3 is set up
for every type using Program 81-06
(T-Bus).
1~5
1
05
CLIP Information Announcement
Based on this setting, the system
includes a Presentation Allowed (1) or
Presentation Restricted (0) in the Setup
message to allow or deny the Calling
Party Number. Program 15-01-04 must
also be set to 1 if this option is enabled.
0=No
1=Yes
1
06
Connection Bus Mode
0 = Extended passive bus
1 = Short passive bus
0
07
S-point DDI digits
0 - 4
0
08
Dial Sending Mode
ISDN Protocol definition
0 = Enblock Sending
1 = Overlap Sending
1
09
Dial Information Element
ISDN Protocol definition
[Only when Dialing Sending Mode
(10-03-08) is set for 1 (Overlap Sending]
0 = Keypad Facility
1 = Called Party Number
1