Issue 10.1 UNIVERGE SV8100
2 - 10 Program 10 : System Configuration Setup
10
Master/Slave System (OT)
If set to 0, system is synchronized to
network clock. If set to 1, system is not
synchronized to the network clock.
0 = Slave System
1=Master System
0
11
Networking System No. (OT)
0 - 50
0
14
Service Protocol for S-point
0 = Keypad facility
1 = Specified Protocol for Aspire
system
0
15
Call Busy Mode for S-point
0=Alerting
1 = Disconnect
0
17
ISDN Line Ringback Tone
If Telco does not provide ringback tone,
SV8100 can if set to 1:Enable.
0 = Disable
1 = Enable
0
18
Type of Number
ISDN Protocol definition
0 = Unknown
1 = International number
2 = National number
3 = Network specific number
4 = Subscriber number
5 = Abbreviated number
0
19
Numbering Plan Identification
ISDN Protocol definition
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering
plan
5 = Private numbering plan
0
22
QSIG Operation Mode
0 = Disable
1 = Enable
0
23
Straight/Cross Wiring
0=Auto
1 = Manual (Cross)
2 = Manual (Straight)
0
24
Power feeding for S-point
0 = Disable
1 = Enable
0
25
Layer1 Supervision
0 = Disable
1 = Enable
0
Item
No
Item Input Data Default