UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 11
For PRTA PKG Setup
ISDN Line Number 01~30
Item
No.
Item Input Data Default
01
ISDN Line Mode
0 = No setting
1=T-Point
2 = S-Point (OT)
3 = NW Mode (Leased Line) (OT)
4 = NW Mode (Interconnected Line)
(OT)
5 = NW Mode (Interconnected Line,
Fixed Layer1=NT) (OT)
6 = S-Point (Leased Line) (OT)
1
02
Logical Port Number
The start port number of a PRI line
is displayed.
0 =) No Set: 0
1 =) T-Point: 1-200
2 =) S-Point: 1-512 (OT)
3 =) NW Mode (Leased Line): 0 (OT)
4 =) NW Mode (Interconnected Line): 0
(OT)
5 =) NW Mode (Interconnected Line,
Fixed Layer1=NT): 0 (OT)
6 =) S-Point (Leased Line): 1-512 (OT)
1
03
CRC Multi-frame(CRC4)
(Only for 2M[30B+D] Mode)
0=off
1=on
1
04
Layer 3 Timer Type
Each timer value of Layer 3 is set
up for each type in
Program 81-06 (T-Bus)
1~5
1
05
CLIP Information
Based on this setting, the system
includes a Presentation Allowed (1) or
Presentation Restricted (0) in the
Setup message to allow or deny the
Calling Party Number. Program
15-01-04 must also be set to 1 if this
option is enabled.
0=No
1=Yes
1
06
Length of Cable
0 = Level 1
1 = Level 2
2 = Level 3
3 = Level 4
4 = Level 5
2
07
S-point DDI digits
0 - 4
0
08
Dial Sending Mode
ISDN Protocol definition
0 = Enbloc Sending
1 = Overlap Sending
1