Issue 10.1 UNIVERGE SV8100
2 - 14 Program 10 : System Configuration Setup
For E1 PKG Setup
05
T1 Clock Source
0 = Internal
1=External
1
06
Number of Ports
0=Auto
1=4 Ports
2=8 Ports
3 = 12 Ports
4 = 16 Ports
5 = 20 Ports
0
07
Straight/Cross Wiring
0 = Auto
1 = Manual (Cross)
2 = Manual (Straight)
0
Physical Port Number 01~30
Item
No.
Item Input Data Default
01
Logical Port Number.
0~200
0
02
Number of channels
0~30
0
03
--- Not Used ---
04
E1 Clock Source
0 = Internal
1=External
1
05
Transmit Pulse Mask
0 = 01 to 133 feet
1 = 133 to 266 feet
2 = 266 to 399 feet
3 = 399 to 533 feet
4 = 533 to 655 feet
0
06
Frame Type
0 = Double Frame (no CRC-4)
1 = Multiframe Structure (CRC-4)
1
07
Line Coding
0 = AMI
1 = HDB3
1
08
--- Not Used ---
09
Straight/Cross Wiring
0 = Straight
1 = Cross
0