EasyManua.ls Logo

NEC Univerge SV8100 - Page 907

NEC Univerge SV8100
986 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 10.1
Programming Manual 2 - 871
13 0 0 Charge
Management
Link Error
The link with the charge
management device came
off.
1. Wiring problem
in connecting main
device with charge
management
device.
2. PC Problem.
1. Confirmed that there
is no problem in wiring
to connect a main
device with the charge
management device.
(Whether ping passes
for LAN connection is
confirmed.)
2. Restart the charge
management software.
3. Reboot PC, and start
charge management
software.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
14 0 0LAN Link
Error
The link with LAN on
CD-CP00 came off.
1. LAN cable
defective.
2. Connected HUB
broken.
3. Defective
CD-CP00
Confirm the operation
of LAN connector, LAN
cable, and HUB again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
15 0 0Network Keep
Alive Error
1. The network connection
has been cut.
2. Network Keep Alive
restoration.
3. Response notification on
network Keep Alive.
1. LAN cable is
defective.
2.Net side trouble.
3. Packet block by
firewall.
4. Repetition of IP
address.
1. Confirm that the
defect is on the Network
side.
2. Confirm the settings
of HUB and the router,
etc.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
WAR
17 1 0 Denial of
service
The system received illegal
packet.
Service outage
(Dos attack)
Confirm whether to find
abnormality on the net
side.l
WAR
29 0 0 Charge
Management
Buffer full
The temporary buffer for
the charge management in
main device overflowed,
and a part of unoutput
charge data disappeared
because it could not output
the charge management
data.
1. The charge data
is printed and not
deleted at the
simple charge
management.
2. The charge data
is not output to PC
for the charge
management
software.
1. Please print and
delete the charge data
at the simple charge
management.
2. Please connect the
charge management
software for the charge
management software
and output the charge
data.
When the
output is
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
ERR
REC
30 2 0 SMDR Buffer
full
The temporary buffer for
SMDR in main device
overflowed, and a part of
unoutput SMDR data
disappeared because it
could not output SMDR
data.
1. Problem of
wiring to connect
main device with
PC.
2. PC Problem.
1. Confirm whether
there is problem in
wiring to connect a
main device with PC.
2. Execute the
reactivation of PC.
When the
output is
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.
ERR
REC
31 1 0 Auto Dial after
Sensor
Detection
Auto dialing occurs after
sensor detection.
Sensor detect an
abnormality and
makes an
emergency call.
No action needed.
32 1 0 Remote
watch
function
performs auto
dial
Remote watch funvtion
performs auto dial
No action needed.
33 1 0 fall to auto
dial by
security
function
Fall to auto dial by security
function.
All auto dial trunks
are busy.
No action needed.
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type Report Name Content of Alarm Cause Action Recovery
Alarm
Status

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals