2 - 872 Program 90 : Maintenance Program
35 0 0 CS Blocking The link of the CSIU and
CS came off.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
The error is
recovered
when
reconnecting
or exchanging
it.
ERR
REC
36 0 0 CS error
notification 1
CS detected the problem
occurring in the air
synchronous signal
between CS-CSIU, BBIC
reset was executed, and it
was restored automatically.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
37 0 0CS
transmission
error.
Because CS had not
returned the response to
the control signal from a
main device longer than
the fixed time, it was
restored automatically
specifying reset to
concerned CS with a main
device.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
38 0 0CSIU Dch
Error×
It was restored
automatically specifying
reset to concerned CS with
a main device because a
main device had detected
the control signal from a
main device not normally
reaching CS.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
39 0 0 CSIU trans-
mission error.
This alarm is integrated
into Communication fault
between the CD-CP00 and
other PKG, and it is not
used in SV8100.
Table 2-20 Description of Alarm (Continued)