e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE and TROUBLESHOOTING
8 - 278
[8103] Wireless Certificate verification failure
[8111] SNMP writing access failure
[8112] SNMP communication failure
[8121] Domain authentication error: Domain authentication error
[8122] Domain authentication error: Invalid user name or password
Classification Error item
Network error Wireless Certificate verification failure
Check item Measures
Setting Verify the certificate settings used for association.
Classification Error item
Network error An error occurred during SNMP data writing.
Check item Measures
Setting Check if the parameter entered in the application is correct.
Check if the entered department code and box password are
correct.
If the error still occurs after the correct parameter is entered,
restart the equipment and the application.
Classification Error item
Network error SNMP communication failed.
Check item Measures
Setting Check if there is any problem in the application.
Classification Error item
Network error An unidentified domain authentication error occurred during
the connection of domain controller.
Check item Measures
Setting Check the network configuration of this equipment and then
reconnect to the domain controller.
Classification Error item
Network error Login is not permitted because the user name or a password
for domain authentication is invalid.
Check item Measures
Setting Check if the user name and the password for this equipment
are correct. Specify upper- and lower-case characters
correctly when you enter them.