e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE and TROUBLESHOOTING
8 - 206
[F122] Database abnormality (message/job log management database)
[F124] Language DB damage error
[F130] Invalid MAC address
[F131] Error due to damage to filtering setting file
Classification Error item
Other service call Login after the startup fails in any starting mode because log
management database is corrupted.
Check item Measures
Setting 1. Delete the log in the following procedure: [5] + [C] +
[POWER] 4. Initialize database 2. Log database
(jobs and messages) (Note that all job and message logs
will be deleted.)
2. If the error is not recovered, reinstall the system software.
([4] + [9] + [POWER] -> 4. System Software(HD data))
Notes:
• If you rebuild the databases with a job remaining,
delete it after finishing.
• When “Rebuilding all databases” is performed, all
data including log/user/role/group/department
information and address book data are deleted. If
you back up the data in advance, they will be
recovered by restoring them after rebuilding the
database.
Classification Error item
Other service call Login after the startup fails in any starting mode because
language management database is corrupted.
Check item Measures
Setting Delete the journal file: [5] + [C] + [START] -> 4. Initialize DB -
> 3. Language DB
If the recovery is still not completed, reinstall the master data
and application program. P. 11-12"11.2.4 Update
procedure"
Classification Error item
Other service call This error occurs when the top 3 bytes of the MAC address is
not “00” “80” “91”.
Check item Measures
SYS board Replace the SYS board.
Classification Error item
Other service call The filtering function is not working properly due to the
damage to the file for the filtering setting.