Device Management Commands 437
Parameter
unit
unit-id
: Specify the Unit ID of the switch.
Description
Use the display boot-loader command to display APP file used for this boot
and the next boot.
Example
<SW5500>display boot-loader
The app to boot of board 0 at the next time is: flash:/platform.app
The app to boot of board 0 at this time is:
flash:/PLATV100R002B09D002.APP
display cpu Syntax
display cpu [ unit
unit-id
]
View
All views.
Parameter
unit
unit-id
: Specify the Unit ID of the switch.
Description
Use the display cpu command to display CPU occupancy.
Example
To display CPU occupancy, enter the following:
<SW5500>display cpu
The information displays in the following format:
CPU busy status:
18% in last 5 seconds
19% in last 1 minute
19% in last 5 minutes
display device Syntax
display device [ unit
unit-id
]
View
All views
Table 54 Display information
Field Description
Board 0 CPU busy status The busy status of the Switch
18% in last 5 seconds The CPU occupancy rate is 18% at last 5 seconds
19% in last 1 minute The CPU occupancy rate is 19% at last 1 minute
19% in last 5 minutes The CPU occupancy rate is 19% at last 5 minutes