Table
4-17
  
Active/Cold
Replacement
Procedure
of
Memory
(continued)
Work
Order
Task Reference
12 Confirming
that
there
is
no
problem
with
the
replacement
memory
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
13 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
14 Incorporating
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
into
a
logical
domain
"10.7
Incorporating
I/O
Resources
Into
a
Logical
Domain"
15 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
*1
Install
memory
of
the
same
type
and
at
the
same
location
as
those
of
the
faulty
memory.
*2
If
the
replaced
memory
was
in
a
SPARC
M12-2S
with
no
PCIe
cards
mounted,
no
diagnosis
is
necessary
(because
diagnosis
was
performed
in
the
previous
step).
Table
4-18
  
Active/Cold
Replacement
Procedure
of
the
BPU
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
from
a
logical
domain
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
4.2.11 Active/Cold
Replacement
Workflow
of
the
BPU
You
can
perform
active/cold
replacement
of
the
BPU
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Table
4-18
shows
the
workflow
for
active/cold
replacement
of
the
BPU.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
202390

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals