Chapter
18
Maintaining
the
Backplane
Unit
and
PSU
Backplane
Unit
This
section
describes
the
maintenance
procedures
for
the
BPU
and
PSUBP
mounted
in
the
SPARC
M12.
Maintenance
Precautions
Locations
of
the
BPU
and
PSUBP
Before
Maintenance
on
the
BPU
and
PSUBP
Removing
the
BPU
and
PSUBP
Installing
the
BPU
and
PSUBP
18.1 Maintenance
Precautions
This
section
describes
precautions
for
maintenance
on
the
BPU
and
the
PSUBP.
Do
not
replace
the
PSUBP
and
the
XSCFU
at
the
same
time.
If
the
PSUBP
and
the
XSCFU
are
replaced
at
the
same
time,
the
system
may
fail
to
operate
normally.
When
you
need
to
replace
the
PSUBP
and
XSCFU,
replace
one
of
the
units
first.
Then,
after
the
XSCF
firmware
starts
up,
power
it
off
again
and
replace
the
other
unit.
Do
not
mount
and
use
any
of
the
following
PSUBP
in
another
chassis:
-
the
one
currently
mounted
in
the
SPARC
M12-2/M12-2S,
or
-
one
that
was
once
used
as
a
maintenance
part
This
is
because
the
above
PSUBP
stores
device
identification
information.
Before
removing
the
BPU,
remove
the
XSCFU,
PCICS,
PSU,
FAN,
FANBPU,
HDDBPU,
CMU,
XBU,
XSCF
DUAL
control
cable,
and
XSCF
BB
control
cable
from
the
BPU.
463