Table
6-17
  
Inactive/Cold
Removal
Procedure
of
a
PCI
Expansion
Unit
(continued)
Work
Order
Task Reference
17 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reconfigure
logical
domains
as
required.
For
details,
see
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
Table
6-18
  
Inactive/Cold
Removal
Procedure
of
the
SPARC
M12-2S
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
I/O
device
usage
status
of
the
SPARC
M12-2S
to
be
removed
"9.2.2
Checking
the
Assignment
Status
of
I/O
Devices"
3 Checking
the
HDD/SSD
usage
status
of
the
SPARC
M12-2S
to
be
removed
"9.2.3
Checking
the
Usage
of
the
HDD/SSD"
4 Powering
off
the
physical
partition
containing
the
SPARC
M12-2S
to
be
removed
"9.5.1
Stopping
a
Specific
Physical
Partition"
5 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
6 Releasing
the
SPARC
M12-2S
from
the
building
block
configuration
(*3)
"9.7
Removing
the
SPARC
M12-2S"
7 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
8 Powering
on
the
physical
partition
of
the
system
after
releasing
the
SPARC
M12-2S
"10.9.1
Starting
the
System
With
an
XSCF
Command"
9 Checking
the
operating
condition
of
the
system
after
releasing
the
SPARC
M12-2S
(*2)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
6.4.6 Inactive/Cold
Removal
Workflow
of
the
SPARC
M12-2S
You
can
perform
inactive/cold
removal
of
the
SPARC
M12-2S
in
the
following
configuration:
â– 
Building
block
configuration
where
two
or
more
physical
partitions
are
operating
Before
removing
the
SPARC
M12-2S,
see
"Precautions
for
SPARC
M12-2S
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-18
shows
the
workflow
for
inactive/cold
removal
of
the
SPARC
M12-2S.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023214

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals