Table
3-8
  
Applicable
Types
of
Maintenance
in
FRU
Replacement
for
the
SPARC
M12-2S
(1BB
Configuration)
-:
Not
applicable
FRU Active
Replacement
Inactive
Replacement
System-Stopped
Replacement
Hot Cold Hot Cold Hot Cold
XSCFU - ---- OK
PCIe
card OK
(*1)---OKOK
PSU OK
(*2)---OKOK
FANU OK
(*2)---OKOK
FANBPU - ---- OK
HDD/SSD OK
(*3)---OKOK
HDDBPU - - - - - OK
OPNL - ---- OK
CMU - ---- OK
Memory - ---- OK
BPU - ---- OK
PSUBP - ---- OK
XBU - ---- OK
PCI
expansion
unit
(chassis) OK - - - OK OK
*1
Maintenance
is
performed
using
the
SR-IOV
function,
dynamic
reconfiguration
function
for
PCIe
devices,
and
PCI
Hot
Plug
function.
*2
This
is
possible
only
if
the
target
FRU
is
in
a
redundant
configuration.
*3
This
is
possible
only
for
the
mirror
volumes
(RAID1
and
RAID1E)
when
the
HDD/SSD
used
as
the
boot
device
is
being
replaced.
3.3 Types
of
Maintenance
Applicable
to
the
SPARC
M12-2S
(1BB
Configuration)
This
section
describes
the
types
of
maintenance
applicable
to
each
FRU
in
the
SPARC
M12-2S
in
the
1BB
configuration,
according
to
the
particular
purpose
of
maintenance.
3.3.1 Types
of
Maintenance
for
FRU
Replacement
(SPARC
M12-2S
in
the
1BB
Configuration)
Table
3-8
lists
the
replaceable
FRUs
in
the
SPARC
M12-2S
(1BB
configuration)
and
the
applicable
types
of
maintenance
in
the
replacement
of
each
FRU.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
202348

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals