Page #245 background imageLoading...
Page #245 background image
Table
6-24
  
System-Stopped/Cold
Removal
Procedure
of
the
CMUU
(continued)
Work
Order
Task Reference
15 Reconfiguring
the
I/O
bus
as
required
(*2) "3.2.18
Configuring
an
I/O
Device"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
16 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
17 Powering
on
all
physical
partitions "10.9.1
Starting
the
System
With
an
XSCF
Command"
18 Checking
the
operating
condition
of
the
physical
partition
and
logical
domains
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
19 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reconfigure
logical
domains
as
required.
For
details,
see
"Chapter
5
Logical
Domain
Configuration
Example"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
*2
When
reconfiguring
the
I/O
bus,
you
may
need
to
reconfigure
the
logical
domains.
Table
6-25
  
System-Stopped/Cold
Removal
Procedure
of
Memory
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Releasing
the
assignment
of
memory
resources
according
to
the
total
capacity
of
memory
after
reduction
"15.2
Changing
the
Memory
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
System
Operation
and
Administration
Guide
3 Confirming
that
you
can
remove
the
CMU
to
be
removed
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
4Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
5 Powering
off
all
physical
partitions "9.5.2
Stopping
All
Physical
Partitions"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
6.6.4 System-Stopped/Cold
Removal
Workflow
of
Memory
Before
removing
the
memory,
see
"Precautions
for
memory
reduction"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-25
shows
the
workflow
for
system-stopped/cold
removal
of
memory.
Chapter
6
 
FRU
Removal
Workflows 223

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals