Table
4-17
  
Active/Cold
Replacement
Procedure
of
Memory
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
from
a
logical
domain
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
7Placing
the
SPARC
M12-2S
requiring
maintenance
into
the
cold
state,
and
remo ving
memory
from
the
SPARC
M12-2S
"17.4
Removing
the
CMU
or
Memory"
8 Installing
memory
in
the
SPARC
M12-2S,
and
placing
the
SPARC
M12-2S
that
required
maintenance
into
the
hot
state
(*1)
"17.5
Installing
the
CMU
and
Memory"
9 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
10 Diagnosing
the
SPARC
M12-2S
with
the
replacement
memory
(*2)
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
11 Diagnosing
the
XBU
and
crossbar
cable
of
the
SPARC
M12-2S
with
the
replacement
memory
"10.5.2
Diagnosing
the
XBU
and
Crossbar
Cable"
4.2.10 Active/Cold
Replacement
Workflow
of
Memory
You
can
perform
active/cold
replacement
of
memory
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
replacing
the
memory,
see
"Precautions
for
CMU
and
memory
replacement"
in
"7.1
Precautions
for
FRU
Replacement."
Table
4-17
shows
the
workflow
for
active/cold
replacement
of
memory.
Chapter
4
 
FRU
Replacement
Workflows 89

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals