Page #243 background imageLoading...
Page #243 background image
Table
6-23
  
System-Stopped/Cold
Removal
Procedure
of
the
HDD/SSD
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Releasing
the
assignment
of
the
I/O
resources
of
the
HDD/SSD
to
be
removed
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
3 Confirming
that
you
can
remove
the
HDD/SSD
to
be
removed
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
4Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
5 Powering
off
all
physical
partitions "9.5.2
Stopping
All
Physical
Partitions"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
7Removing
the
power
cords
of
all
the
SPARC
M12-2/M12-2S
units
"9.8.2
Removing
the
Power
Cords"
8Removing
the
HDD/SSD
to
be
removed
from
the
SPARC
M12-2/M12-2S
"15.3.1
Removing
an
HDD/SSD"
9 Installing
the
filler
unit
in
the
SPARC
M12-2/M12-2S
"15.4.2
Installing
a
Filler
Unit"
10 Installing
the
power
cords
of
all
the
SPARC
M12-2/M12-2S
units
"10.1.1
Installing
a
Power
Cord"
11 Powering
on
all
physical
partitions "10.9.1
Starting
the
System
With
an
XSCF
Command"
12 Confirming
that
there
is
no
problem
with
the
system
from
which
the
HDD/SSD
was
removed
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
13 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
14 Checking
the
operating
condition
of
the
physical
partition
and
logical
domains
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
15 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reconfigure
logical
domains
as
required.
For
details,
see
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
If
you
have
reconfigured
a
logical
domain,
save
the
logical
domain
configuration
information.
6.6.2 System-Stopped/Cold
Removal
Workflow
of
the
HDD/SSD
Before
removing
the
HDD/SSD,
see
"Precautions
for
HDD/SSD
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-23
shows
the
workflow
for
system-stopped/cold
removal
of
the
HDD/SSD.
Chapter
6
 
FRU
Removal
Workflows 221

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals