EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #223 background imageLoading...
Page #223 background image
Table
6-8
  
Active/Cold
Removal
Procedure
of
a
PCI
Expansion
Unit
(continued)
Work
Order
Task Reference
15 Incorporating
the
SPARC
M12-2S
from
which
the
PCI
expansion
unit
was
removed
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
16 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
17 Checking
the
operating
condition
of
the
physical
partition
and
logical
domains
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
18 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reassign
I/O
resources
to
logical
domains
as
required.
For
details,
see
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
Table
6-9
  
Active/Cold
Removal
Procedure
of
the
SPARC
M12-2S
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
I/O
device
usage
status
of
the
SPARC
M12-2S
to
be
removed
"9.2.2
Checking
the
Assignment
Status
of
I/O
Devices"
3 Checking
the
HDD/SSD
usage
status
of
the
SPARC
M12-2S
to
be
removed
"9.2.3
Checking
the
Usage
of
the
HDD/SSD"
4 Checking
the
assignment
status
of
CPU
resources
to
logical
domains
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
5 Checking
the
assignment
status
of
memory
resources
to
logical
domains
"3.2.5
Checking
the
Usage
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
6.2.6 Active/Cold
Removal
Workflow
of
the
SPARC
M12-2S
You
can
perform
active/cold
removal
of
the
SPARC
M12-2S
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
removing
the
SPARC
M12-2S,
see
"Precautions
for
SPARC
M12-2S
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-9
shows
the
workflow
for
active/cold
removal
of
the
SPARC
M12-2S.
Chapter
6
 
FRU
Removal
Workflows 201

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals