Initial
diagnosis
has
completed.
PSB
power
off
sequence
started.
[1200sec]
0.....
30.....end
PSB
powered
off.
PSB
Test
Fault
----
-------
--------
00-0
Passed
Normal
done
------------------------------------------------------------------------------
Maintenance/Replacement
Menu
Status
of
the
replaced
FRU.
 
FRU
Status
-------------------
--------------
/BB#0
Normal
------------------------------------------------------------------------------
The
replacement
of
BB#0
has
completed
normally.[f:finish]
:
f
------------------------------------------------------------------------------
Maintenance/Replacement
Menu
Please
select
the
chassis
including
replaced
FRU.
No.
FRU
Status
---
-------------------
--------------
1
/BB#0
Normal
2
/BB#1
Normal
3
/BB#2
Normal
4
/BB#3
Normal
------------------------------------------------------------------------------
Select
[1-4|c:cancel]
:
c
XSCF>
3.
Check
the
hardware
diagnosis
result.
Check
that
Normal
is
displayed
under
Status.
Then,
enter
"f"
to
finish
the
maintenance
of
the
SPARC
M12-2S.
If
the
displayed
status
is
abnormal
(Degrade
or
Fault),
finish
the
maintenance
of
the
SPARC
M12-2S
and
return
to
the
maintenance
start
screen.
Perform
maintenance
on
the
SPARC
M12-2S
again,
and
check
whether
the
replaced
FRU
is
correctly
mounted.
4.
End
the
replacefru
command.
When
the
maintenance
start
screen
appears,
enter
"c"
to
end
the
replacefru
command.
10.4.2 Incorporating
the
FANU
This
section
describes
the
procedure
for
incorporating
the
FANU
into
the
system.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
January
2023340

Table of Contents

Related product manuals