Table
6-13
  
Inactive/Cold
Removal
Procedure
of
a
PCIe
Card
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Releasing
the
assignment
of
the
I/O
resources
of
the
PCIe
card
to
be
removed
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
3 Confirming
that
you
can
remove
the
PCIe
card
to
be
removed
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
4Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
5 Powering
off
the
physical
partition
containing
the
SPARC
M12-2S
that
houses
the
PCIe
card
to
be
removed
"9.5.1
Stopping
a
Specific
Physical
Partition"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
7 Releasing
the
SPARC
M12-2S
that
houses
the
PCIe
card
to
be
removed,
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
8Removing
the
PCICS
in
which
the
PCIe
card
to
be
removed
is
mounted
from
the
SPARC
M12-2S
"12.3.1
Enabling
the
Removal
of
a
PCIe
Card"
Before
performing
removal
work,
be
sure
to
check
the
notes
on
maintenance
work
in
the
Fujitsu
SPARC
M12
Product
Notes
of
the
XCP
version
used.
Each
of
the
following
sections
puts
together
the
order
of
work
and
the
tasks
for
each
FRU
into
a
table.
For
details
on
each
task,
see
the
reference
shown
in
the
table.
The
following
FRUs
are
subject
to
inactive/cold
removal:
â– 
PCIe
card
â– 
HDD/SSD
â– 
CMUU
â– 
Memory
â– 
PCI
expansion
unit
â– 
SPARC
M12-2S
6.4.1 Inactive/Cold
Removal
Workflow
of
a
PCIe
Card
You
can
perform
inactive/cold
removal
of
a
PCIe
card
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
removing
a
PCIe
card,
see
"Precautions
for
PCIe
card
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-13
shows
the
workflow
for
inactive/cold
removal
of
a
PCIe
card.
Chapter
6
 
FRU
Removal
Workflows 207

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals