Caution
-
Remove
all
HDDs/SSDs
from
the
HDDBPU.
Replacing
the
OPNL
without
removing
the
HDDs/SSDs
may
damage
them.
Caution
-
The
CMUU
weighs
10
kg
(22
lb).
Work
must
be
done
by
two
people
if
the
chassis
is
mounted
at
the
24U
or
higher
position
of
the
rack.
If
the
work
is
done
by
one
person,
it
may
result
in
an
injury
or
damage
to
the
chassis.
configuration,
confirm
that
the
target
PCIe
card
can
be
removed
from
the
multipath
I/O
configuration.
For
details,
see
the
manual
for
the
software
being
used.
â– 
To
perform
active
replacement
in
combination
with
the
dynamic
SR-IOV
function
or
the
dynamic
reconfiguration
function
for
a
PCIe
endpoint,
the
PCIe
card
to
be
replaced
must
support
the
respective
function.
For
details,
see
"Appendix
C
Cards/On-Board
Devices
That
Support
SR-IOV"
and
"Appendix
D
Cards/On-Board
Devices
That
Support
Assignment
of
PCIe
End
Point
Devices
(PCIe
Cards)"
in
the
Fujitsu
SPARC
M12
PCI
Card
Installation
Guide.
Precautions
for
OPNL
replacement
â– 
When
replacing
the
OPNL
in
the
SPARC
M12-2S,
set
the
BB-ID
of
the
OPNL
after
replacement
to
the
same
value
as
that
used
before
replacement.
7.2 Precautions
for
FRU
Expansion
This
section
describes
the
precautions
for
FRU
expansion.
Before
performing
expansion
work,
see
"(3)
Checking
the
FRU
status"
in
"8.2.2
Identifying
a
Fault"
to
confirm
that
there
is
no
problem
with
the
chassis
requiring
expansion.
Precautions
for
CMUU
expansion
â– 
When
adding
the
CMUU,
remove
the
CMU
filler
unit.
Store
the
removed
CMU
filler
unit
in
a
safe
place.
â– 
Adding
the
CMUU
also
adds
a
root
complex.
Enabling
the
I/O
bus
reconfiguration
function
increases
the
I/O
bandwidth.
Since
doing
so
changes
the
PCIe
card
installation
rules
and
the
device
path
of
the
I/O
device,
you
may
need
to
reconfigure
the
logical
domains.
For
details,
see
"A.2
SPARC
M12-2
Device
Paths"
or
"A.3
SPARC
M12-2S
Device
Paths"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
System
Operation
and
Administration
Guide.
â– 
To
use
the
added
CPU
resources
after
CMUU
addition,
you
need
to
assign
CPU
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023230

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals