Caution
-
The
CMUU
weighs
10
kg
(22
lb),
and
the
CMUL
weighs
13
kg
(29
lb).
Work
must
be
done
by
two
people
if
the
chassis
is
mounted
at
the
24U
or
higher
position
of
the
rack.
If
the
work
is
done
by
one
person,
it
may
result
in
an
injury
or
damage
to
the
chassis.
Activations.
Check
the
number
of
CPU
Activation
keys
registered
with
the
device
and
the
number
of
CPU
Activations
assigned
to
the
physical
partition,
before
using
them.
â– 
To
add
a
CMUU
with
64
GB
DIMMs
mounted,
see
"Notes
on
Memory"
in
the
latest
version
of
the
Fujitsu
SPARC
M12
Product
Notes.
Precautions
for
memory
expansion
â– 
In
memory
expansion,
observe
the
memory
installation
rules.
For
details,
see
"2.2.1
Memory
Installation
Rules."
â– 
To
mount
a
64
GB
DIMM,
see
"Notes
on
Memory"
in
the
latest
version
of
the
Fujitsu
SPARC
M12
Product
Notes.
Precautions
for
HDD/SSD
addition
â– 
When
adding
the
HDD/SSD,
remove
the
filler
unit
from
the
slot
in
which
the
HDD
or
SSD
will
be
mounted.
Store
the
removed
filler
unit
in
a
safe
place.
Precautions
for
PCIe
card
addition
â– 
When
performing
active
addition
using
PCI
Hot
Plug,
confirm
that
the
PCIe
card
supports
PCI
Hot
Plug.
For
details,
see
"Appendix
B
Cards
That
Support
PCI
Hot
Plug
and
Dynamic
Reconfiguration"
in
the
Fujitsu
SPARC
M12
PCI
Card
Installation
Guide.
â– 
To
perform
active
addition
in
combination
with
the
dynamic
SR-IOV
function
or
the
dynamic
reconfiguration
function
for
a
PCIe
endpoint,
the
PCIe
card
to
be
added
must
support
the
respective
function.
For
details,
see
"Appendix
C
Cards/On-Board
Devices
That
Support
SR-IOV"
and
"Appendix
D
Cards/On-Board
Devices
That
Support
Assignment
of
PCIe
End
Point
Devices
(PCIe
Cards)"
in
the
Fujitsu
SPARC
M12
PCI
Card
Installation
Guide.
â– 
To
add
a
PCIe
card,
remove
the
PCIe
card
filler
from
the
PCICS.
Store
the
removed
filler
in
a
safe
place.
Precautions
for
SPARC
M12-2S
addition
â– 
The
SPARC
M12-2S
to
be
added
to
a
building
block
configuration
must
have
the
XSCF
settings
information
initialized.
To
add
a
SPARC
M12-2S
that
has
been
used
in
another
system,
initialize
the
setting
information
before
adding
it.
â– 
If
you
power
on
the
initialized
SPARC
M12-2S
before
adding
it
to
a
building
block
configuration,
the
BB-ID
of
the
OPNL
is
set
in
the
XSCF,
possibly
making
it
Chapter
7
 
FRU
Maintenance
Precautions 231

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals