EasyManuals Logo
Home>Fujitsu>Server>Oracle SPARC M12-2

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #369 background imageLoading...
Page #369 background image
XSCF>
testsb
-v
-p
-s
-y
01-0
Initial
diagnosis
is
about
to
start,
Continue?[y|n]
:
y
PSB#01-0
power
on
sequence
started.
:
(Omitted)
:
/pci@8500/pci@4/pci@0/pci@0/scsi@0
FCode
Version
1.00.56,
MPT
Version
2.00,
Firmware
Version
20.00.10.00
Target
a
Unit
0
Encl
Serv
device
FUJITSU
BBEXP
1303
SASAddress
500000e0e0b0117d
PhyNum
14
/pci@8100/pci@4/pci@0/pci@0/scsi@0
FCode
Version
1.00.56,
MPT
Version
2.00,
Firmware
Version
20.00.10.00
Target
a
Unit
0
Disk
TOSHIBA
AL13SEB600
3703
1172123568
Blocks,
600
GB
SASDeviceName
50000396f8120578
SASAddress
50000396f812057a
PhyNum
0
Target
b
Unit
0
Disk
TOSHIBA
AL13SEB600
3703
1172123568
Blocks,
600
GB
SASDeviceName
50000396f8120498
SASAddress
50000396f812049a
PhyNum
1
Target
c
Unit
0
Encl
Serv
device
FUJITSU
BBEXP
1303
SASAddress
500000e0e0b0117d
PhyNum
14
:
10.5.1 Diagnosing
the
SPARC
M12
Hardware
This
section
describes
the
procedure
for
performing
a
hardware
diagnosis
on
the
SPARC
M12.
If
the
CMUL
has
been
replaced,
confirm
that
the
combination
of
the
CMUL
and
XSCFU
types
is
correct
by
using
the
showhardconf
command,
before
performing
step
(1)
or
(2)
below.
For
details,
see
Table
8-2
in
"8.1.6
Checking
FRU
Information."
Select
either
step
(1)
or
(2)
below
to
perform
a
hardware
diagnosis
on
the
SPARC
M12
with
the
testsb
command.
(1)
Diagnosing
the
SPARC
M12
by
specifying
its
PSB
(2)
Diagnosing
all
the
SPARC
M12
units
For
a
configuration
with
only
one
SPARC
M12-2
or
SPARC
M12-2S,
either
of
steps
(1)
and
(2)
can
be
selected
for
the
diagnosis.
<Description
of
options>
-v:
Displays
a
detailed
message
on
the
hardware
diagnosis.
-p:
Displays
the
storage
connected
to
the
SPARC
M12.
-s:
Displays
the
device
tree.
-a:
Diagnoses
all
the
mounted
SPARC
M12
units.
If
you
do
not
specify
-a,
you
need
to
specify
the
PSB
of
the
SPARC
M12-2S
to
be
diagnosed.
(1) Diagnosing
the
SPARC
M12
by
specifying
its
PSB
The
following
example
runs
the
hardware
diagnosis
on
the
SPARC
M12-2S
with
PSB
01-0
and
checks
the
I/O
connections.
Chapter
10
 
Setting
Up
the
System 347

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals