EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
Table
5-4
  
Active/Cold
Addition
Procedure
of
a
PCIe
Card
(continued)
Work
Order
Task Reference
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
7 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration,
and
removing
the
power
cords
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
"9.8.2
Removing
the
Power
Cords"
8Removing
the
PCICS
from
the
SPARC
M12-2S
"12.3.1
Enabling
the
Removal
of
a
PCIe
Card"
9Removing
the
PCIe
card
filler
from
the
PCICS
"12.3.2
Removing
a
PCIe
Card
or
PCIe
Card
Filler"
10 Installing
a
PCIe
card
in
the
PCICS
to
install
it
in
the
SPARC
M12-2S
"12.4.1
Installing
a
PCIe
Card
or
PCIe
Card
Filler"
11 Installing
the
power
cords
on
the
SPARC
M12-2S
with
the
added
PCIe
card,
and
incorporating
it
into
the
building
block
configuration
"10.1.1
Installing
a
Power
Cord"
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
12 Diagnosing
the
SPARC
M12-2S
with
the
added
PCIe
card
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
13 Confirming
that
there
is
no
problem
with
the
added
PCIe
card
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
14 Incorporating
the
SPARC
M12-2S
with
the
added
PCIe
card
into
the
physical
partition
"
10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
15 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
16 Assigning
the
I/O
resource
to
a
logical
domain
"3.2
Operations
and
Commands
Related
to
Logical
Domain
Configurations"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
5.2.2 Active/Cold
Addition
Workflow
of
the
HDD/SSD
You
can
perform
active/cold
addition
of
the
HDD/SSD
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
adding
the
HDD/SSD,
see
"Precautions
for
HDD/SSD
addition"
in
"7.2
Precautions
for
FRU
Expansion."
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023156

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals