Page #248 background image
Table
6-27
  
System-Stopped/Cold
Removal
Procedure
of
the
SPARC
M12-2S
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
I/O
device
usage
status
of
the
SPARC
M12-2S
to
be
removed
"9.2.2
Checking
the
Assignment
Status
of
I/O
Devices"
3 Checking
the
HDD/SSD
usage
status
of
the
SPARC
M12-2S
to
be
removed
"9.2.3
Checking
the
Usage
of
the
HDD/SSD"
4 Powering
off
all
physical
partitions "9.5.2
Stopping
All
Physical
Partitions"
5 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
6 Releasing
the
SPARC
M12-2S
to
be
removed,
from
the
physical
partition
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration
"
7 Releasing
the
SPARC
M12-2S
from
the
building
block
configuration
"9.7
Removing
the
SPARC
M12-2S"
8 Diagnosing
all
the
connected
SPARC
M12-2S
units
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
9 Confirming
that
there
is
no
problem
with
the
SPARC
M12-2S
released
from
the
physical
partition
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
10 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
11 Powering
on
all
physical
partitions "10.9.1
Starting
the
System
With
an
XSCF
Command"
12 Checking
the
operating
condition
of
the
system
(*2)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
13 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
If
the
removal
of
the
SPARC
M12-2S
does
not
affect
logical
domains,
this
work
is
not
required.
*2
Reconfigure
logical
domains
as
required.
For
details,
see
"Chapter
3
Operations
for
Domain
Configuration"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
6.6.6 System-Stopped/Cold
Removal
Workflow
of
the
SPARC
M12-2S
You
can
perform
system-stopped/cold
removal
of
the
SPARC
M12-2S
in
the
following
configuration:
â– 
Multiple-BB
configuration
Before
removing
the
SPARC
M12-2S,
see
"Precautions
for
SPARC
M12-2S
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-27
shows
the
workflow
for
system-stopped/cold
removal
of
the
SPARC
M12-2S.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023226

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals