YES
Is LED of power
supply unit off?
Did you receive an
error report from the
XSCF mail function?
Check OS Console
for an error message
Log in to the XSCF and check for
fault information in showlogs output
In Oracle Solaris, check the error
messages in /var/adm/messages
Record displayed fault information
Contact field engineer
Is power cord
connected properly?
Connect power cord
properly
Figure
8-1
  
Troubleshooting
Flow
8.2.2 Identifying
a
Fault
This
section
describes
how
to
identify
a
fault.
Identify
the
location
of
a
fault
by
following
the
troubleshooting
flow
in
Figure
8-1.
(1)
Checking
the
LED
indicators
Check
the
LEDs
on
the
OPNL,
rear
panel,
and
individual
units
to
identify
the
FRU
requiring
maintenance.
For
FRU
maintenance,
check
the
status
with
the
LEDs
before
starting
the
maintenance.
â– 
LEDs
of
the
OPNL
Chapter
8
 
Preparation
for
Maintenance 249

Table of Contents