Page #272 background imageLoading...
Page #272 background image
Note
-
Some
FRUs
such
as
memory
do
not
have
mounted
LEDs.
To
check
the
status
of
a
FRU
without
a
mounted
LED,
use
an
XSCF
command
such
as
the
showhardconf
command.
For
details,
see
"(3)
Checking
the
FRU
status"
below.
XSCF>
showlogs
monitor
Jan
27
18:42:11
H4U2S115
Event:
SCF:System
powered
on
Jan
27
18:45:41
H4U2S115
Event:
SCF:PPAR-ID
0:
Reset
released
Jan
27
18:45:48
H4U2S115
Event:
SCF:POST
boot
start
from
PPAR
(PPAR
ID
0)
Jan
27
18:45:49
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
Banner)
Jan
27
18:45:50
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
CPU
Check)
Jan
27
18:45:51
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
CPU
Register)
Jan
27
18:45:52
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
STICK
Increment)
Jan
27
18:45:53
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
Extended
Instruction)
Jan
27
18:45:54
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
MMU)
Jan
27
18:46:07
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
Memory
Initialize)
Jan
27
18:46:43
H4U2S115
Event:
SCF:Current
PPARs'
phase
(PPARID
0
POST
phase:
MSCAN)
You
can
check
the
system
status
from
the
LEDs
on
the
OPNL.
For
details,
see
"2.4.1
OPNL
LEDs."
â– 
Rear
panel
LEDs
As
with
the
CHECK
LED
on
the
OPNL,
you
can
also
check
the
system
status
from
the
CHECK
LED
on
the
rear
of
the
SPARC
M12-2/M12-2S.
For
details,
see
"2.4.2
System
Locator."
â– 
LEDs
of
individual
FRUs
From
the
FRU
LEDs,
you
can
locate
not
only
any
error
occurrence
in
hardware
in
the
SPARC
M12-2/M12-2S
but
also
the
hardware
that
caused
the
error.
For
details,
see
"2.4.3
LEDs
of
Each
Unit."
(2)
Checking
error
messages
If
a
failure
occurs
in
the
system,
analyze
the
failure
cause
from
the
failure
occurrence
time,
abnormal
event,
and
other
data
obtained
from
XSCF
log
information
and
Oracle
Solaris
messages.
Checking
XSCF
log
information
The
following
example
shows
a
check
of
system
operation
and
failure
information
from
XSCF
log
information.
For
details,
see
"12.1
Checking
a
Log
Saved
by
the
XSCF"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
System
Operation
and
Administration
Guide.
â– 
Checking
monitoring
messages
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023250

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals