EasyManuals Logo
Home>Fujitsu>Server>Oracle SPARC M12-2

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #217 background imageLoading...
Page #217 background image
Table
6-5
  
Active/Cold
Removal
Procedure
of
the
HDD/SSD
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
the
logical
domain
assignment
of
all
the
HDD/SSD
and
PCIe
cards
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
HDD/SSD
and
PCIe
cards
mounted
in
the
SPARC
M12-2S
requiring
maintenance,
from
the
system
"9.4
Enabling
the
Removal
of
Hardware"
6 Confirming
that
you
can
release
the
SPARC
M12-2S
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
7 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
8 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
9 Confirming
that
the
physical
partition
and
logical
domains
continue
operating
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
10 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
11 Removing
the
HDD/SSD
from
the
SPARC
M12-2S
"
15.3.1
Removing
an
HDD/SSD"
12
Installing
a
filler
unit
in
the
SPARC
M12-2S
"15.4.2
Installing
a
Filler
Unit"
6.2.2 Active/Cold
Removal
Workflow
of
the
HDD/SSD
You
can
perform
active/cold
removal
of
the
HDD/SSD
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
removing
the
HDD/SSD,
see
"Precautions
for
HDD/SSD
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-5
shows
the
workflow
for
active/cold
removal
of
the
HDD/SSD.
Chapter
6
 
FRU
Removal
Workflows 195

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals