Caution
-
The
CMUU
weighs
10
kg
(22
lb),
and
the
CMUL
weighs
13
kg
(29
lb).
Work
must
be
done
by
two
people
if
the
chassis
is
mounted
at
the
24U
or
higher
position
of
the
rack.
If
the
work
is
done
by
one
person,
it
may
result
in
an
injury
or
damage
to
the
chassis.
to
two
CPUs
and
with
the
I/O
bus
reconfigured
-
State
where
the
I/O
bus
reconfiguration
function
is
disabled
on
a
system
with
a
CPU
configuration
of
two
CPUs
at
initial
installation
To
use
all
the
PCI
slots,
enable
the
I/O
bus
reconfiguration
function
and
change
the
I/O
device
path.
However,
you
may
need
to
reconfigure
the
logical
domains
because
the
I/O
device
path
changes.
Precautions
for
memory
reduction
â– 
In
memory
reduction,
observe
the
memory
installation
rules.
For
details,
see
"2.2.1
Memory
Installation
Rules."
â– 
When
reducing
memory,
you
may
need
to
reconfigure
the
logical
domains.
For
details,
see
"3.2.14
Configuring
Virtual
Memory"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
Precautions
for
HDD/SSD
removal
â– 
When
removing
the
HDD/SSD,
mount
the
filler
unit
in
the
empty
slot.
Precautions
for
PCIe
card
removal
â– 
When
using
the
PCI
Hot
Plug
function
for
active
removal
of
a
PCIe
card
having
a
multipath
setting,
you
may
need
to
release
the
target
PCIe
card
from
the
multipath
configuration.
See
the
manual
for
the
multipath
software
being
used.
â– 
When
performing
active
removal
using
PCI
Hot
Plug,
confirm
that
the
PCIe
card
supports
PCI
Hot
Plug.
For
details,
see
"Appendix
B
Cards
That
Support
PCI
Hot
Plug
and
Dynamic
Reconfiguration"
in
the
Fujitsu
SPARC
M12
PCI
Card
Installation
Guide.
â– 
To
perform
active
removal
in
combination
with
the
dynamic
SR-IOV
function
or
the
dynamic
reconfiguration
function
for
a
PCIE
endpoint,
confirm
that
the
card
supports
the
respective
function.
See
"Appendix
C
Cards/On-Board
Devices
That
Support
SR-IOV"
and
"Appendix
D
Cards/On-Board
Devices
That
Support
Assignment
of
PCIe
End
Point
Devices
(PCIe
Cards)"
in
the
Fujitsu
M12
PCI
Card
Installation
Guide.
â– 
After
removing
the
PCIe
card,
install
a
PCIe
card
filler
in
the
PCICS
and
then
mount
the
PCICS
in
the
SPARC
M12-2/M12-2S.
Precautions
for
SPARC
M12-2S
removal
â– 
To
remove
a
SPARC
M12-2S
from
a
building
block
configuration,
use
a
method
other
than
system-stopped/cold
removal.
Performing
system-stopped/cold
Chapter
7
 
FRU
Maintenance
Precautions 233

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals