EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #246 background image
Table
6-25
  
System-Stopped/Cold
Removal
Procedure
of
Memory
(continued)
Work
Order
Task Reference
7Removing
the
power
cords
of
all
the
SPARC
M12-2/M12-2S
units
"9.8.2
Removing
the
Power
Cords"
8 Enabling
the
removal
of
the
CMU "17.4.1
Enabling
the
Removal
of
the
CMU"
9Removing
the
CMU
of
the
memory
to
be
removed
from
the
SPARC
M12-2/M12-2S
"17.4.2
Removing
the
CMU"
10
Removing
the
memory
from
the
CMU
(*2)
"17.4.3
Removing
Memory"
11 Installing
the
CMU
from
which
the
memory
was
removed,
in
the
SPARC
M12-2/M12-2S
"17.5.2
Installing
the
CMU"
12 Assembling
the
SPARC
M12-2/M12-2S
from
which
the
memory
was
removed
"17.5.3
Restoring
the
Server"
13 Installing
the
power
cords
of
all
the
SPARC
M12-2/M12-2S
units
"10.1.1
Installing
a
Power
Cord"
14 Diagnosing
all
the
SPARC
M12-2/M12-2S
units
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
15 Confirming
that
there
is
no
problem
with
the
system
from
which
the
memory
was
removed
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
16 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
17 Powering
on
all
physical
partitions "
10.9.1
Starting
the
System
With
an
XSCF
Command"
18 Checking
the
operating
condition
of
the
physical
partition
and
logical
domains
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
19 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reconfigure
logical
domains
as
required.
For
details,
see
"Chapter
5
Logical
Domain
Configuration
Example"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
*2
Observe
the
installation
rules
to
remove
memory.
For
details,
see
"2.2
Checking
the
Memory
Configuration
Rules."
6.6.5 System-Stopped/Cold
Removal
Workflow
of
the
PCI
Expansion
Unit
Table
6-26
shows
the
workflow
for
system-stopped/cold
removal
of
a
PCI
expansion
unit.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023224

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals