EasyManuals Logo
Home>Fujitsu>Server>Oracle SPARC M12-2

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Table
5-7
  
Active/Cold
Addition
Procedure
of
Memory
(continued)
Work
Order
Task Reference
16 Assigning
the
resources
of
the
added
SPARC
M12-2S
to
logical
domains
"3.2
Operations
and
Commands
Related
to
Logical
Domain
Configurations"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
*1
If
the
CMUU
has
no
memory
installed,
install
memory
before
installing
the
CMUU
in
the
SPARC
M12-2S.
*2
If
the
memory
was
added
to
a
SPARC
M12-2S
with
no
PCIe
cards
mounted,
no
diagnosis
is
necessary
(because
diagnosis
was
performed
in
the
previous
step).
Table
5-8
  
Active/Cold
Addition
Procedure
of
a
PCI
Expansion
Unit
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
the
logical
domain
assignment
of
PCIe
cards
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
5.2.5 Active/Cold
Addition
Workflow
of
the
PCI
Expansion
Unit
You
can
perform
active/cold
addition
of
a
PCI
expansion
unit
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
adding
the
PCI
expansion
unit,
mount
it
in
the
rack.
(See
"3.4
Mounting
the
SPARC
M12-2S
and
the
PCI
Expansion
Unit
in
a
Rack"
in
the
Fujitsu
SPARC
M12-2S
Installation
Guide.)
Table
5-8
shows
the
workflow
for
active/cold
addition
of
a
PCI
expansion
unit.
Chapter
5
 
FRU
Addition
Workflows 161

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals