Note
-
The
hot
replacement
of
the
XSCFU
is
possible
only
in
a
building
block
configuration
connecting
multiple
SPARC
M12-2S
units.
When
maintaining
the
XSCFU
in
a
configuration
using
only
one
SPARC
M12-2
or
SPARC
M12-2S,
remove
the
power
cord
and
perform
system-stopped/cold
replacement.
Chapter
11
Maintaining
the
XSCF
Unit
This
section
describes
the
maintenance
procedures
for
the
XSCFU
mounted
in
the
SPARC
M12-2/M12-2S.
â– 
Maintenance
Precautions
â– 
Location
of
the
XSCFU
â– 
Before
Maintenance
on
the
XSCFU
â– 
Removing
the
XSCFU
â– 
Switching
an
SD
Card
â– 
Installing
the
XSCFU
11.1 Maintenance
Precautions
Note
the
following
points
when
you
maintain
the
XSCFU.
â– 
Do
not
replace
the
XSCFU
and
the
PSUBP
at
the
same
time.
If
the
XSCFU
and
the
PSUBP
are
replaced
at
the
same
time,
the
system
may
fail
to
operate
normally.
â– 
Do
not
mount
and
use
any
of
the
following
SD
cards
in
the
XSCFU
in
another
chassis:
-
the
one
currently
mounted
in
the
SPARC
M12-2/M12-2S,
or
-
one
that
was
once
used
as
a
maintenance
part
This
is
because
these
SD
cards
store
device
identification
information.
â– 
If
you
replace
the
SD
card
along
with
the
XSCFU,
dispose
of
the
SD
card
mounted
on
the
old
XSCFU
by
appropriate
means
such
as
cutting
it
with
cutting
pliers.
The
old
SD
card
stores
the
user
information,
IP
address,
and
other
information
set
373

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals