EasyManuals Logo
Home>Fujitsu>Server>Oracle SPARC M12-2

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #239 background imageLoading...
Page #239 background image
Table
6-20
  
System-Stopped/Hot
Removal
Procedure
of
the
HDD/SSD
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
usage
status
of
the
HDD/SSD
to
be
removed
"9.2.3
Checking
the
Usage
of
the
HDD/SSD"
3 Releasing
the
HDD/SSD
resources
assigned
to
logical
domains
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain
"
4 Confirming
that
you
can
release
the
HDD/SSD
to
be
removed
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
5Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
6 Powering
off
all
physical
partitions "9.5.2
Stopping
All
Physical
Partitions"
7 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
8Removing
the
HDD/SSD
from
the
SPARC
M12-2/M12-2S
"15.3.1
Removing
an
HDD/SSD"
9 Installing
the
filler
unit
in
the
SPARC
M12-2/M12-2S
"15.4.2
Installing
a
Filler
Unit"
10 Powering
on
all
physical
partitions "10.9.1
Starting
the
System
With
an
XSCF
Command"
11 Confirming
that
there
is
no
problem
with
the
system
from
which
the
HDD/SSD
was
removed
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
12 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
13 Checking
the
operating
condition
of
the
system
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
14 Saving
logical
domain
configuration
information
"
9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reassign
I/O
resources
to
logical
domains
as
required.
For
details,
see
"3.2.18
Configuring
an
I/O
Device"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
6.5.3 System-Stopped/Hot
Removal
Workflow
of
the
PCI
Expansion
Unit
Table
6-21
shows
the
workflow
for
system-stopped/hot
removal
of
a
PCI
expansion
unit.
Chapter
6
 
FRU
Removal
Workflows 217

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals