EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background image
Table
3-5
  
Applicable
Types
of
Maintenance
in
FRU
Replacement
for
the
SPARC
M12-2
-:
Not
applicable
FRU Active
Replacement
Inactive
Replacement
System-Stopped
Replacement
Hot Cold Hot Cold Hot Cold
XSCFU - ---- OK
PCIe
card OK
(*1)---OKOK
PSU OK
(*2)---OKOK
FANU OK
(*2)---OKOK
FANBPU - - - - - OK
HDD/SSD OK
(*3)---OKOK
HDDBPU - - - - - OK
OPNL - - - - - OK
CMU - ---- OK
Memory - - - - - OK
BPU - ---- OK
PSUBP - ---- OK
PCI
expansion
unit
(chassis) OK - - - OK OK
*1
Maintenance
is
performed
using
the
SR-IOV
function,
dynamic
reconfiguration
function
for
PCIe
devices,
and
PCI
Hot
Plug
function.
*2
This
is
possible
only
if
the
target
FRU
is
in
a
redundant
configuration.
*3
This
is
possible
only
for
the
mirror
volumes
(RAID1
and
RAID1E)
when
the
HDD/SSD
used
as
the
boot
device
is
being
replaced.
3.2 Types
of
Maintenance
Applicable
to
the
SPARC
M12-2
This
section
describes
the
types
of
maintenance
applicable
to
each
FRU
of
the
SPARC
M12-2,
according
to
the
particular
purpose
of
maintenance.
Inactive
maintenance
is
not
available
for
the
SPARC
M12-2.
Inactive
maintenance
is
possible
only
in
systems
that
use
the
SPARC
M12-2S
in
a
building
block
configuration.
3.2.1 Types
of
Maintenance
for
FRU
Replacement
(SPARC
M12-2)
Table
3-5
lists
the
replaceable
FRUs
in
the
SPARC
M12-2
and
the
applicable
types
of
maintenance
in
the
replacement
of
each
FRU.
Chapter
3
 
Understanding
the
Types
of
Maintenance 43

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals