Table
4-50
  
System-Stopped/Hot
Replacement
Procedure
of
the
HDD/SSD
(continued)
Work
Order
Task Reference
6Removing
the
HDD/SSD
from
the
SPARC
M12-2/M12-2S
"15.3.1
Removing
an
HDD/SSD"
7 Installing
an
HDD/SSD
in
the
SPARC
M12-2/M12-2S
"15.4.1
Installing
an
HDD/SSD"
8 Powering
on
the
physical
partitions "10.9.1
Starting
the
System
With
an
XSCF
Command"
9 Confirming
that
there
is
no
problem
with
the
replacement
HDD/SSD
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
10 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
11 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
Table
4-51
  
System-Stopped/Hot
Replacement
Procedure
of
a
PCI
Expansion
Unit
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Confirming
the
PCI
expansion
unit
to
be
replaced
"8.2
Troubleshooting"
3 Checking
the
operation
status
of
the
SPARC
M12-2/M12-2S
connected
to
the
PCI
expansion
unit
to
be
replaced
PCI
Expansion
Unit
for
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Service
Manual
4 Stopping
all
physical
partitions "9.5.2
Stopping
All
Physical
Partitions"
5 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
6Removing
the
FRUs
in
the
faulty
PCI
expansion
unit
PCI
Expansion
Unit
for
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Service
Manual
4.5.6 System-Stopped/Hot
Replacement
Workflow
of
the
PCI
Expansion
Unit
Table
4-51
shows
the
workflow
for
system-stopped/hot
replacement
of
a
PCI
expansion
unit.
Table
4-51
describes
the
procedure
for
replacing
a
FRU
while
the
power
cords
of
the
PCI
expansion
unit
are
disconnected.
For
replacement
procedures
for
FRUs
while
the
power
cords
of
the
PCI
expansion
unit
are
connected,
see
"7.1.1
Hot
Replacement"
in
the
PCI
Expansion
Unit
for
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Service
Manual.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023130

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals