EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #427 background imageLoading...
Page #427 background image
Note
-
You
can
remove
a
FANU
in
the
active
state.
Note
-
You
can
remove
the
FANBPU
only
when
the
server
is
in
the
cold
state.
Note
-
The
serial
number
of
the
server
is
printed
on
a
label
affixed
on
the
front
cover.
Store
this
cover
such
that
it
is
not
mixed
up
with
the
front
covers
of
other
SPARC
M12
units.
When
replacing
a
FANU,
perform
one
of
the
maintenance
procedures
listed
below.
[When
replacing
a
FANU
with
the
server
in
the
hot
state]
-
4.1.4
Active/Hot
Replacement
Workflow
of
the
FANU
-
4.3.4
Inactive/Hot
Replacement
Workflow
of
the
FANU
-
4.5.4
System-Stopped/Hot
Replacement
Workflow
of
the
FANU
 
[When
replacing
a
FANU
with
the
server
in
the
cold
state]
-
4.2.4
Active/Cold
Replacement
Workflow
of
the
FANU
-
4.4.4
Inactive/Cold
Replacement
Workflow
of
the
FANU
-
4.5.4
System-Stopped/Hot
Replacement
Workflow
of
the
FANU
14.3 Removing
a
FANU
or
the
FANBPU
This
section
describes
the
procedure
for
removing
a
FANU
or
FANBPU.
14.3.1 Removing
a
FANU
This
section
describes
the
procedure
for
removing
a
FANU.
1.
Remove
the
front
cover.
For
the
procedure
for
removing
the
front
cover,
see
"9.8.3
Removing
the
Front
Cover."
2.
Pull
up
the
latch
of
the
FANU.
Pinch
the
latch
of
the
FANU
(A
in
Figure
14-2)
and
pull
it
up.
Chapter
14
 
Maintaining
the
Fan
Units
and
Fan
Backplane
Unit 405

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals