Table
4-15
  
Active/Cold
Replacement
Procedure
of
the
OPNL
(continued)
Work
Order
Task Reference
7Placing
the
SPARC
M12-2S
requiring
maintenance
into
the
cold
state,
and
removing
the
OPNL
from
the
SPARC
M12-2S
"16.3
Removing
the
HDDBPU
or
OPNL"
8
Installing
the
OPNL
on
the
SPARC
M12-2S,
and
placing
the
SPARC
M12-2S
that
required
maintenance
into
the
hot
state
(*1)
"16.4
Installing
the
HDDBPU
or
OPNL"
9 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
10 Confirming
that
there
is
no
problem
with
the
replacement
OPNL
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
11 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
12 Incorporating
I/O
resources
of
the
SPARC
M12-2S
requiring
maintenance
into
a
logical
domain
"10.7
Incorporating
I/O
Resources
Into
a
Logical
Domain"
13 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
*1
Confirm
that
the
set
BB-ID
is
the
same
as
that
of
the
faulty
OPNL.
Table
4-16
  
Active/Cold
Replacement
Procedure
of
the
CMU
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
and
the
I/O
device
usage
status
"9.2
Checking
the
Operation
Status
and
Resource
Usage
Status
of
Oracle
Solaris"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4.2.9 Active/Cold
Replacement
Workflow
of
the
CMU
You
can
perform
active/cold
replacement
of
the
CMU
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
replacing
the
CMU,
see
"Precautions
for
CMU
and
memory
replacement"
in
"7.1
Precautions
for
FRU
Replacement."
Table
4-16
shows
the
workflow
for
active/cold
replacement
of
the
CMU.
Chapter
4
 
FRU
Replacement
Workflows 87

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals