Page #180 background image
Table
5-5
  
Active/Cold
Addition
Procedure
of
the
HDD/SSD
(continued)
Work
Order
Task Reference
15 Assigning
the
I/O
resource
to
a
logical
domain
"3.2
Operations
and
Commands
Related
to
Logical
Domain
Configurations"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
Table
5-6
  
Active/Cold
Addition
Procedure
of
the
CMUU
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
the
logical
domain
assignment
of
PCIe
cards
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
7 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration,
and
removing
the
power
cords
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
"9.8.2
Removing
the
Power
Cords"
8Removing
the
filler
unit
from
the
SPARC
M12-2S
"17.4
Removing
the
CMU
or
Memory"
5.2.3 Active/Cold
Addition
Workflow
of
the
CMUU
You
can
perform
active/cold
addition
of
the
CMUU
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
adding
the
CMUU,
see
"Precautions
for
CMUU
expansion"
in
"7.2
Precautions
for
FRU
Expansion."
Table
5-6
shows
the
workflow
for
active/cold
addition
of
the
CMUU.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023158

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals