EasyManuals Logo

Fujitsu Oracle SPARC M12-2 User Manual

Fujitsu Oracle SPARC M12-2
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
Table
5-5
  
Active/Cold
Addition
Procedure
of
the
HDD/SSD
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
the
logical
domain
assignment
of
PCIe
cards
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
5 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
physical
partition
"9.4.3
Dynamically
Releasing
the
SPARC
M12-2S
From
the
Physical
Partition"
6 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
7 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration,
and
removing
the
power
cords
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
"
9.8.2
Removing
the
Power
Cords"
8Removing
the
filler
unit
from
the
SPARC
M12-2S
"15.3.2
Removing
a
Filler
Unit"
9 Installing
an
HDD/SSD
in
the
SPARC
M12-2S
"15.4.1
Installing
an
HDD/SSD"
10 Installing
the
power
cords
on
the
SPARC
M12-2S
with
the
added
HDD/SSD,
and
incorporating
it
into
the
building
block
configuration
"10.1.1
Installing
a
Power
Cord"
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
11 Diagnosing
the
SPARC
M12-2S
with
the
added
HDD/SSD
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
12 Confirming
that
there
is
no
problem
with
the
added
HDD/SSD
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
13 Incorporating
the
SPARC
M12-2S
with
the
added
HDD/SSD
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
14 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
Table
5-5
shows
the
workflow
for
active/cold
addition
of
the
HDD/SSD.
Chapter
5
 
FRU
Addition
Workflows 157

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals