Page #218 background imageLoading...
Page #218 background image
Table
6-5
  
Active/Cold
Removal
Procedure
of
the
HDD/SSD
(continued)
Work
Order
Task Reference
13 Incorporating
the
SPARC
M12-2S
from
which
HDD/SSD
was
removed
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
14 Incorporating
the
SPARC
M12-2S
into
the
physical
partition
"10.6.1
Incorporating
the
SPARC
M12-2S
Into
the
Physical
Partition
Using
PPAR
DR"
15 Switching
the
mode
switch
on
the
OPNL
to
Locked
"2.3.2
OPNL
Control
Function"
16 Checking
the
operating
condition
of
the
physical
partition
and
logical
domains
(*1)
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
17 Saving
logical
domain
configuration
information
"9.1.1
Saving
Logical
Domain
Configuration
Information"
*1
Reassign
I/O
resources
to
logical
domains
as
required.
For
details,
see
"3.2.18
Configuring
an
I/O
Device"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide.
Table
6-6
  
Active/Cold
Removal
Procedure
of
the
CMUU
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
the
logical
domain
assignment
of
all
the
PCIe
cards
and
HDD/SSD
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
6.2.3 Active/Cold
Removal
Workflow
of
the
CMUU
You
can
perform
active/cold
removal
of
the
CMUU
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
removing
the
CMUU,
see
"Precautions
for
CMUU
removal"
in
"7.3
Precautions
for
FRU
Reduction."
Table
6-6
shows
the
workflow
for
active/cold
removal
of
the
CMUU.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023196

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals