Page #128 background imageLoading...
Page #128 background image
Table
4-30
  
Inactive/Cold
Replacement
Procedure
of
a
PCIe
Card
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Confirming
the
PCIe
card
to
be
replaced "8.2
Troubleshooting"
3 Checking
the
operation
status
of
the
SPARC
M12-2S
that
houses
the
PCIe
card
to
be
replaced
PCI
Expansion
Unit
for
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Service
Manual
4 Powering
off
the
physical
partition
containing
the
SPARC
M12-2S
that
houses
the
PCIe
card
requiring
maintenance
"9.5.1
Stopping
a
Specific
Physical
Partition"
5 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
6 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
7Placing
the
SPARC
M12-2S
requiring
maintenance
into
the
cold
state
"9.8.2
Removing
the
Power
Cords"
8Removing
the
faulty
PCIe
card
from
the
SPARC
M12-2S
"12.3.1
Enabling
the
Removal
of
a
PCIe
Card"
9Removing
the
faulty
PCIe
card
from
the
PCICS
"12.3.2
Removing
a
PCIe
Card
or
PCIe
Card
Filler"
10 Installing
the
replacement
PCIe
card
in
the
PCICS
to
install
it
in
the
SPARC
M12-2S
"12.4.1
Installing
a
PCIe
Card
or
PCIe
Card
Filler"
11 Placing
the
SPARC
M12-2S
that
required
maintenance
into
the
hot
state
"10.1.1
Installing
a
Power
Cord"
12 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
13 Diagnosing
the
SPARC
M12-2S
requiring
maintenance
"10.5.1
Diagnosing
the
SPARC
M12
Hardware"
4.4.2 Inactive/Cold
Replacement
Workflow
of
a
PCIe
Card
You
can
perform
inactive/cold
replacement
of
a
PCIe
card
in
the
following
configuration:
â– 
Building
block
configuration
where
two
or
more
physical
partitions
are
operating
Before
replacing
the
PCIe
card,
see
"Precautions
for
PCIe
card
replacement"
in
"7.1
Precautions
for
FRU
Replacement."
Table
4-30
shows
the
workflow
for
inactive/cold
replacement
of
a
PCIe
card.
Fujitsu
SPARC
M12-2/M12-2S
Service
Manual
ï½¥
January
2023106

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals