Page #127 background imageLoading...
Page #127 background image
Table
4-29
  
Inactive/Cold
Replacement
Procedure
of
the
XSCFU
(continued)
Work
Order
Task Reference
3 Confirming
that
the
XSCFU
to
be
replaced
is
the
standby
or
slave
XSCF
and
is
currently
replaceable
(*1)
"Table
2-16
XSCFU
LEDs
and
Their
States"
4 Powering
off
the
physical
partition
containing
the
SPARC
M12-2S
that
houses
the
XSCFU
to
be
replaced
"9.5.1
Stopping
a
Specific
Physical
Partition"
5 Switching
the
mode
switch
on
the
OPNL
to
Service
"2.3.2
OPNL
Control
Function"
6 Releasing
the
SPARC
M12-2S
requiring
maintenance
from
the
building
block
configuration
"9.6.1
Releasing
the
SPARC
M12-2S
From
the
Building
Block
Configuration"
7Placing
the
SPARC
M12-2S
requiring
maintenance
into
the
cold
state
"9.8.2
Removing
the
Power
Cords"
8Removing
the
XSCFU
from
the
SPARC
M12-2S
"11.4
Removing
the
XSCFU"
9 Switching
the
SD
card
(*2) "11.5
Switching
an
SD
Card"
10
Installing
the
XSCFU
in
the
SPARC
M12-2S
"11.6
Installing
the
XSCFU"
11 Placing
the
SPARC
M12-2S
that
required
maintenance
into
the
hot
state
"10.1.1
Installing
a
Power
Cord"
12 Incorporating
the
SPARC
M12-2S
that
required
maintenance
into
the
building
block
configuration
"10.4.1
Incorporating
the
SPARC
M12-2S
Into
a
Building
Block
Configuration"
13 Confirming
that
there
is
no
problem
with
the
replacement
XSCFU
"10.5.3
Checking
the
FRU
Status
After
Maintenance"
14 Switching
the
mode
switch
on
the
OPNL
to
Locked,
and
powering
on
the
physical
partition
containing
the
SPARC
M12-2S
that
has
undergone
maintenance
"10.8
Powering
on
a
Physical
Partition"
15 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
*1
Before
replacing
the
XSCFU,
confirm
that
the
READY
LED
of
the
XSCFU
is
lit
in
green
or
off.
If
the
READY
LED
of
the
XSCFU
is
blinking,
wait
until
the
LED
stays
lit
or
is
turned
off.
-
If
the
XSCFU
requiring
replacement
is
not
running
when
the
physical
partition
containing
the
XSCFU
is
powered
on,
perform
active/hot
replacement.
-
If
the
physical
partition
containing
the
XSCFU
requiring
replacement
is
powered
off,
you
can
perform
hot
replacement
of
the
XSCFU
even
when
it
is
not
running.
In
that
case,
proceed
to
step
5.
*2
If
the
SD
card
installed
in
the
maintenance
part
will
be
used,
this
work
is
not
required.
Chapter
4
 
FRU
Replacement
Workflows 105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals