Table
5-4
  
Active/Cold
Addition
Procedure
of
a
PCIe
Card
Work
Order
Task Reference
1 Checking
the
operating
condition
of
the
system
"9.2.1
Checking
the
Operation
Status
of
Physical
Partitions
and
Logical
Domains"
2 Checking
the
logical
domain
assignment
status
of
CPU
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
3 Checking
the
logical
domain
assignment
status
of
memory
resources
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"3.2.4
Checking
the
Assignment
Status
of
Resources"
in
the
Fujitsu
SPARC
M12
and
Fujitsu
M10/SPARC
M10
Domain
Configuration
Guide
4 Releasing
the
logical
domain
assignment
of
PCIe
cards
mounted
in
the
SPARC
M12-2S
requiring
maintenance
"9.3
Releasing
I/O
Resources
From
a
Logical
Domain"
M12-2S
and
active/cold
addition
of
the
SPARC
M12-2S.
Since
active/cold
addition
uses
physical
partition
(PPAR)
DR,
it
is
supported
only
in
a
building
block
configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition.
Before
performing
addition
work,
be
sure
to
check
the
notes
on
maintenance
work
in
the
Fujitsu
SPARC
M12
Product
Notes
of
the
XCP
version
used.
Each
of
the
following
sections
puts
together
the
order
of
work
and
the
tasks
for
each
FRU
into
a
table.
For
details
on
each
task,
see
the
reference
shown
in
the
table.
The
following
FRUs
are
subject
to
active/cold
addition:
â– 
PCIe
card
â– 
HDD/SSD
â– 
CMUU
â– 
Memory
â– 
PCI
expansion
unit
â– 
SPARC
M12-2S
5.2.1 Active/Cold
Addition
Workflow
of
a
PCIe
Card
You
can
perform
active/cold
addition
of
a
PCIe
card
in
the
following
configuration:
â– 
Configuration
connecting
two
or
more
SPARC
M12-2S
units
to
a
physical
partition
Before
adding
the
PCIe
card,
see
"Precautions
for
PCIe
card
addition"
in
"7.2
Precautions
for
FRU
Expansion."
Table
5-4
shows
the
workflow
for
active/cold
addition
of
a
PCIe
card.
Chapter
5
 
FRU
Addition
Workflows 155

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Oracle SPARC M12-2 and is the answer not in the manual?

Fujitsu Oracle SPARC M12-2 Specifications

General IconGeneral
BrandFujitsu
ModelOracle SPARC M12-2
CategoryServer
LanguageEnglish

Related product manuals